Tuesday, February 07, 2012

Site Search

Vacuum Switches

Vacuum switches - 230 V

 

Direct switching of electrical consumers.

  • Switching point adjustable (factory setting is 400 mbars absolute)
  • Protection class IP-55

 

 

 

 

 

Item Number
Adjustable range [absolute mbars] Repeat accuracy [mbars] Hysteresis
[mbars]
Electrical
capacity [A]
Weight [g]
12 02 10
10-930 3 100 3 103

 

Vacuum switches - Electronic

 

Fully electronic supervision of vacuum systems in order to minimize cycle times and/or to maximize the process safety. Can be used as a measuring or switching element. Suitable for control loops.

  • Maximum flexibility, since the switching point and hysteresis can be programmed as desired
  • Versatility of application by one analog and one digital output
  • Highest level of accuracy and maximum durability as a result of the fully electronic design
  • Easy operation using 3 keys and dual-coloured LEDs

 

 

 

Item Number
Measuring range [absolute bars] Overpressure safety
[absolute mbars]
Repeat accuracy [mbars] Digital switching outputs Maximum switching current [mA] Analog output [V]
20 020
0-1 6 +/- 2 PNP
(NO or NC)
125 1-5
Supply voltage [V] Current consumption
[mA]
Protecion class Operating temperature [°C] Permissible media Weight [g]
11-30 < 25 65 0-50 Dry, oil-free air and non-abrasive gases 20

 

Vacuum switches - Electronic, with display

 

Fully electronic supervision of vacuum systems in order to minimize cycle times and/or to maximize the process safety. Can be used as a switching element with two isolated digital outputs. Suitable for control loops.

  • Maximum flexibility, since the switching points and hysteresis can be programmed as desired
  • Two limit values retrievable using two isolated switching outputs
  • Highest level of accuracy and maximum durability as a result of the fully electronic design
  • Easy operation using 3 keys and LCD display
  • Supplementary indication using dual-colored LEDs
  • With degree of vacuum display via LCD

 

 

 

Item Number
Measuring range [absolute bars] Overpressure safety
[absolute mbars]
Repeat accuracy [mbars] Digital switching outputs Maximum switching current [mA] Analog output [V]
20 020
0-1 6 +/- 2 PNP
(NO or NC)
125 1-5
Supply voltage [V] Current consumption
[mA]
Protecion class Operating temperature [°C] Permissible media Weight [g]
11-30 < 25 65 0-50 Dry, oil-free air and non-abrasive gase

Official UK FIPA Agents

fipalogo.jpg